Journal Information
Vol. 98. Issue 4.
Pages 271-275 (May 2007)
Vol. 98. Issue 4.
Pages 271-275 (May 2007)
Case report
Full text access
Cutaneous Adverse Reaction to Bio-Alcamid® Implant
Reacción Cutánea Tras Implante con Bio-Alcamid®
Visits
8092
E. Gómez-de la Fuentea,
Corresponding author
egomezf@fhalcorcon.es

Correspondence: Unidad de Dermatología, Fundación Hospital Alcorcón, C/ Budapest 1, 28922 Alcorcón, Madrid, Spain.
, J.G. Álvarez-Fernándeza, F. Pinedob, E. Naza, R. Gama, F.J. Vicente-Martína, J.L. López-Estebaranza
a Unidad de Dermatología, Fundación Hospital Alcorcón, Madrid, Spain
b Unidad de Anatomía Patológica, Fundación Hospital Alcorcón, Madrid, Spain
This item has received
Article information
Abstract
Bibliography
Download PDF
Statistics
Abstract

In the last years new and numerous materials for the correction of defects and wrinkles have been developed. One of these materials is Bio-Alcamid®, a non reabsorbable gel polymer constituted by meshes of poly-alkyl-imide, without known adverse effects. We report a 34-year-old woman that had Bio-Alcamid® implants for acne scars and several months after presented nodular lesions together with a painful inflammatory nodule. The nodule was drained and culture of the purulent material yielded Streptococcus viridans. A cytology and a cellular block of that material showed a granulomatous inflammatory reaction together with a foreign body. The different types of reactions to implants and their pathogenic mechanism are discussed. It is important to know these possible reactions to filler materials given their increasing use and the potential medico-legal consequences.

Key words:
Bio-Alcamid®
filler substances
foreign body granuloma
Resumen

En los últimos años se ha producido la aparición de nuevos y numerosos materiales para la corrección de defectos y arrugas. Uno de estos materiales es el Bio-Alcamid®, un gel polimérico gelatinoso no reabsorbible constituido por redes del grupo alquilimida, del cual no hay descritos efectos adversos. Presentamos una mujer de 34 años que recibió inyecciones de Bio-Alcamid® por cicatrices post-acné presentando varios meses después lesiones nodulares, junto con un nódulo inflamatorio muy doloroso. Fue drenado extrayéndose gran cantidad de material purulento y cultivándose un Streptococcus grupo viridans. Se realizó una citología y un bloque celular de ese material donde se objetivó una reacción inflamatoria granulomatosa junto con un material extraño.

Se discuten los diversos tipos de reacciones a implantes y su mecanismo patogénico. Es importante el conocimiento de estas posibles reacciones a los materiales de relleno por el incremento debido a un mayor uso y por las consecuencias médicas y legales.

Palabras clave:
Bio-Alcamid®
sustancias de relleno
granuloma a cuerpo extraño
Full text is only aviable in PDF
References
[1.]
A.W. Klein, M.L. Elson.
The history of substances for soft tissue augmentation.
Dermatol Surg, 26 (2000), pp. 1096-1105
[2.]
American Society of Aesthetic Plastic Surgery http://www.surgery.org. Accessed June 2006.
[3.]
C. Requena, M.J. Izquierdo, M. Navarro, A. Martínez, J.J. Vilata, R. Botella, et al.
Adverse reactions to injectable aesthetic microimplants.
Am J Dermatopathol, 23 (2001), pp. 197-202
[4.]
T. Lombardi, J. Samson, F. Plantier, C. Husson, R. Küffer.
Orofacial granulomas after injection of cosmetic fillers. Histopathologic and clinical study of 11 cases.
J Oral Pathol Med, 33 (2004), pp. 115-120
[5.]
G. Lemperle, V. Morhenn, U. Charrier.
Human histology and persistence of various injectable filler substances for soft tissue augmentation.
Aesth Plast Surg, 27 (2003), pp. 354-366
[6.]
L. Christensen, V. Breiting, M. Janssen, J. Vuust, E. Hogdall.
Adverse reaction to injectable soft tissue permanent fillers.
Aesth Plast Surg, 29 (2005), pp. 34-48
[7.]
S. Paccini, M. Ruggiero, G. Morucci, N. Cammarota, C. Protopapa, M. Gulisano.
Bio-alcamid: a novelty for reconstructive and cosmetic surgery.
Ital J Anat Embryol, 107 (2002), pp. 209-214
[8.]
P.A. Ramires, M.A. Miccoli, E. Panzarini, L. Dini, C. Protopapa.
In vitro and in vivo biocompatibility evaluation of a polyalkylimide hydrogel for soft tissue augmentation.
J Biomed Mater Res B Appl Biomater, 72 (2005), pp. 230-238
[9.]
Bio-AlcamidTM Subcutaneous augmentation material. The first injectable endoprosthesis. http://www.mediform.com/productos/. Accessed June 2006.
[10.]
C. Serrano, S. Serrano.
Infección demorada tras el uso de Bio-Alcamid®.
Actas Dermosifiliogr, 97 (2006), pp. 460-462
[11.]
R.B. Karim, J.J. Hage, L. van Rozelaar, C.A. Lange, J. Raaijmakers.
Complications of polyalkylimide 4% injections (Bio-Alcamid): a report of 18 cases.
J Plast Reconstr Aesthet Surg, 59 (2006), pp. 1409-1414
[12.]
C.P. Virden, M.K. Dobke, P. Stein.
Subclinical infection of the silicone breast implant surface as a possible cause of capsular contracture.
Aesth Plast Surg, 16 (1992), pp. 173-179
[13.]
A. Parhiscar, G. Har-El.
Deep neck abscess: a retrospective review of 210 cases.
Ann Otol Rhinol Laryngol, 10 (2001), pp. 1051-1054
[14.]
K. De Boulle.
Management of complications after implantation of fillers.
J Cosmet Dermatol, 3 (2004), pp. 2-15
Copyright © 2007. Academia Española de Dermatología y Venereología and Elsevier España, S.L.
Download PDF
Idiomas
Actas Dermo-Sifiliográficas
Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?