se ha leído el artículo
array:23 [ "pii" => "S0001731023006191" "issn" => "00017310" "doi" => "10.1016/j.ad.2022.07.049" "estado" => "S300" "fechaPublicacion" => "2023-10-01" "aid" => "3610" "copyright" => "AEDV" "copyrightAnyo" => "2022" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "crp" "cita" => "Actas Dermosifiliogr. 2023;114:T844-T845" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "itemAnterior" => array:18 [ "pii" => "S0001731022010614" "issn" => "00017310" "doi" => "10.1016/j.ad.2022.07.031" "estado" => "S300" "fechaPublicacion" => "2023-10-01" "aid" => "3345" "copyright" => "AEDV" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "crp" "cita" => "Actas Dermosifiliogr. 2023;114:844-5" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "es" => array:11 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta científico-clínica</span>" "titulo" => "Utilidad de la técnica de «water-bath» en la ecografía cutánea" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "844" "paginaFinal" => "845" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Usefulness of the Water Bath Technique in Ultrasound Skin Imaging" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1311 "Ancho" => 1505 "Tamanyo" => 162631 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">A) Esquirla de cristal (flecha blanca) en el 3.° dedo visualizada mediante ecografía clínica con B) Técnica «water-bath». C) Esquirla de cristal extraída.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Y. Tung-Chen, M. Rodríguez Pérez, P.H. Huimann, M. Sanz-Lozano, R. Tejada Sorados" "autores" => array:5 [ 0 => array:2 [ "nombre" => "Y." "apellidos" => "Tung-Chen" ] 1 => array:2 [ "nombre" => "M." "apellidos" => "Rodríguez Pérez" ] 2 => array:2 [ "nombre" => "P.H." "apellidos" => "Huimann" ] 3 => array:2 [ "nombre" => "M." "apellidos" => "Sanz-Lozano" ] 4 => array:2 [ "nombre" => "R." "apellidos" => "Tejada Sorados" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001731022010614?idApp=UINPBA000044" "url" => "/00017310/0000011400000009/v1_202310020456/S0001731022010614/v1_202310020456/es/main.assets" ] "asociados" => array:1 [ 0 => array:18 [ "pii" => "S0001731022010614" "issn" => "00017310" "doi" => "10.1016/j.ad.2022.07.031" "estado" => "S300" "fechaPublicacion" => "2023-10-01" "aid" => "3345" "copyright" => "AEDV" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "crp" "cita" => "Actas Dermosifiliogr. 2023;114:844-5" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "es" => array:11 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta científico-clínica</span>" "titulo" => "Utilidad de la técnica de «water-bath» en la ecografía cutánea" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "844" "paginaFinal" => "845" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Usefulness of the Water Bath Technique in Ultrasound Skin Imaging" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1311 "Ancho" => 1505 "Tamanyo" => 162631 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">A) Esquirla de cristal (flecha blanca) en el 3.° dedo visualizada mediante ecografía clínica con B) Técnica «water-bath». C) Esquirla de cristal extraída.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Y. Tung-Chen, M. Rodríguez Pérez, P.H. Huimann, M. Sanz-Lozano, R. Tejada Sorados" "autores" => array:5 [ 0 => array:2 [ "nombre" => "Y." "apellidos" => "Tung-Chen" ] 1 => array:2 [ "nombre" => "M." "apellidos" => "Rodríguez Pérez" ] 2 => array:2 [ "nombre" => "P.H." "apellidos" => "Huimann" ] 3 => array:2 [ "nombre" => "M." "apellidos" => "Sanz-Lozano" ] 4 => array:2 [ "nombre" => "R." "apellidos" => "Tejada Sorados" ] ] ] ] ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001731022010614?idApp=UINPBA000044" "url" => "/00017310/0000011400000009/v1_202310020456/S0001731022010614/v1_202310020456/es/main.assets" ] ] "en" => array:15 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Case and Research Letter</span>" "titulo" => " Usefulness of the Water-Bath Technique in Ultrasound Skin Imaging" "tieneTextoCompleto" => true "saludo" => "To the Editor:" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "T844" "paginaFinal" => "T845" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "Y. Tung-Chen, M. Rodríguez Pérez, P.H. Huimann, M. Sanz-Lozano, R. Tejada Sorados" "autores" => array:5 [ 0 => array:4 [ "nombre" => "Y." "apellidos" => "Tung-Chen" "email" => array:1 [ 0 => "yale.tung.chen@gmail.com" ] "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 1 => array:3 [ "nombre" => "M." "apellidos" => "Rodríguez Pérez" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] 2 => array:3 [ "nombre" => "P.H." "apellidos" => "Huimann" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] 3 => array:3 [ "nombre" => "M." "apellidos" => "Sanz-Lozano" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">d</span>" "identificador" => "aff0020" ] ] ] 4 => array:3 [ "nombre" => "R." "apellidos" => "Tejada Sorados" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">e</span>" "identificador" => "aff0025" ] ] ] ] "afiliaciones" => array:5 [ 0 => array:3 [ "entidad" => "Departamento de Medicina Interna, Hospital Universitario Puerta de Hierro-Majadahonda, Majadahonda, Madrid, Spain" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Departamento de Medicina Interna, Hospital Universitario y Politécnico La Fe, Valencia, Spain" "etiqueta" => "b" "identificador" => "aff0010" ] 2 => array:3 [ "entidad" => "Departamento de Neurología, Hospital Universitario Puerta de Hierro-Majadahonda, Majadahonda, Madrid, Spain" "etiqueta" => "c" "identificador" => "aff0015" ] 3 => array:3 [ "entidad" => "Hospital Universitario Puerta de Hierro-Majadahonda, Majadahonda, Madrid, Spain" "etiqueta" => "d" "identificador" => "aff0020" ] 4 => array:3 [ "entidad" => "Hospital Universitario La Paz, Spain" "etiqueta" => "e" "identificador" => "aff0025" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Corresponding author." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Utilidad de la técnica de «water-bath» en la ecografía cutánea" ] ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1312 "Ancho" => 1505 "Tamanyo" => 168045 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">A, Glass splinter (white arrow) in the third finger visualized by clinical ultrasound using the water-bath technique (B). C, Surgically removed glass splinter.</p>" ] ] ] "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">Clinical ultrasound techniques have undergone significant advances in recent years and are routinely used to support clinical assessment in emergency situations.</p><p id="par0010" class="elsevierStylePara elsevierViewall">A 62-year-old woman with no remarkable past history presented with a stabbing pain in the pulp of the third left finger that had started after she had been handling glass. There were no visible lesions, but the pain persisted despite analgesics (paracetamol 1<span class="elsevierStyleHsp" style=""></span>g/8<span class="elsevierStyleHsp" style=""></span>h).</p><p id="par0015" class="elsevierStylePara elsevierViewall">Suspecting a foreign body, we examined the patient's finger using ultrasound with a linear ultrasound probe and the water-bath technique (in which tissue is immersed in a liquid medium). The ultrasound showed a hyperechogenic image corresponding to a glass splinter in the pulp of the finger (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1A and B</a>).</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0020" class="elsevierStylePara elsevierViewall">The splinter was surgically removed in the plastic surgery department (<a class="elsevierStyleCrossRef" href="#fig0005">Fig. 1C</a>).</p><p id="par0025" class="elsevierStylePara elsevierViewall">The water-bath technique is a painless procedure that produces high-quality images of superficial structures without the need for ultrasound gel or contact between the probe and the skin.<a class="elsevierStyleCrossRef" href="#bib0005"><span class="elsevierStyleSup">1</span></a> It is used to examine small, irregular surfaces where contact with the probe is lost and the proximity of the organ or structure being examined results in a suboptimal image in the middle of the screen. By performing the examination in a deeper liquid medium (in this case the water in the bath where the hand is immersed), the entire surface to examine is in contact with the liquid surface and can also be positioned in the middle of the ultrasound field, substantially improving the quality of the resulting image.</p><p id="par0030" class="elsevierStylePara elsevierViewall">Ultrasound using the water-bath technique is primarily used to detect foreign bodies in extremities or other small, irregular, superficial structures; evaluate certain skin or soft tissue infections (e.g., abscesses); and examine musculoskeletal and/or tendon injuries.</p><p id="par0035" class="elsevierStylePara elsevierViewall">The procedure is as follows. First, immerse the part of the body to be examined in a container filled with serum or warm water. Then insert the ultrasound probe and place it perpendicular to the skin at a distance of approximately 1<span class="elsevierStyleHsp" style=""></span>cm to capture the images. There is no need for ultrasound gel or contact between the probe and the patient's skin, as water is an excellent conductor.</p><p id="par0040" class="elsevierStylePara elsevierViewall">Clinical ultrasound using the water-bath technique can detect foreign bodies that are difficult to visualize or localize by physical examination. Although this technique is underused, it is a safe and simple tool that should be borne in mind for examining small, irregular, superficial structures.</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Conflicts of Interest</span><p id="par0045" class="elsevierStylePara elsevierViewall">There are no conflicts of interest.</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:2 [ 0 => array:2 [ "identificador" => "sec0005" "titulo" => "Conflicts of Interest" ] 1 => array:1 [ "titulo" => "Reference" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "multimedia" => array:1 [ 0 => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figure 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1312 "Ancho" => 1505 "Tamanyo" => 168045 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">A, Glass splinter (white arrow) in the third finger visualized by clinical ultrasound using the water-bath technique (B). C, Surgically removed glass splinter.</p>" ] ] ] "bibliografia" => array:2 [ "titulo" => "Reference" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0015" "bibliografiaReferencia" => array:1 [ 0 => array:3 [ "identificador" => "bib0005" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Water bath evaluation technique for emergency ultrasound of painful superficial structures" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "M. Blaivas" 1 => "M. Lyon" 2 => "L. Brannam" 3 => "S. Duggal" 4 => "P. Sierzenski" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.ajem.2004.09.009" "Revista" => array:6 [ "tituloSerie" => "Am J Emerg Med" "fecha" => "2004" "volumen" => "22" "paginaInicial" => "589" "paginaFinal" => "593" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15666267" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/00017310/0000011400000009/v1_202310020456/S0001731023006191/v1_202310020456/en/main.assets" "Apartado" => array:4 [ "identificador" => "6160" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Cartas científico-clínicas" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/00017310/0000011400000009/v1_202310020456/S0001731023006191/v1_202310020456/en/main.pdf?idApp=UINPBA000044&text.app=https://actasdermo.org/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0001731023006191?idApp=UINPBA000044" ]
año/Mes | Html | Total | |
---|---|---|---|
2024 Noviembre | 13 | 8 | 21 |
2024 Octubre | 121 | 53 | 174 |
2024 Septiembre | 114 | 46 | 160 |
2024 Agosto | 116 | 67 | 183 |
2024 Julio | 86 | 36 | 122 |
2024 Junio | 79 | 35 | 114 |
2024 Mayo | 81 | 38 | 119 |
2024 Abril | 51 | 34 | 85 |
2024 Marzo | 66 | 39 | 105 |
2024 Febrero | 56 | 36 | 92 |
2024 Enero | 53 | 22 | 75 |
2023 Diciembre | 45 | 21 | 66 |
2023 Noviembre | 86 | 49 | 135 |
2023 Octubre | 93 | 56 | 149 |
2023 Septiembre | 44 | 53 | 97 |
2023 Agosto | 70 | 81 | 151 |
2023 Julio | 8 | 30 | 38 |