Intraoperative gamma imaging of axillary sentinel lymph nodes in breast cancer patients

https://doi.org/10.1016/S1120-1797(06)80030-XGet rights and content

Abstract

Sentinel lymph node (SLN) biopsy is now standard practice in the management of many breast cancer patients. Localization protocols vary in complexity and rates of success. The least complex involve only intraoperative gamma counting of radiotracer uptake or intraoperative visualization of blue-dye uptake; the most complex involve preoperative gamma imaging, intraoperative counting and intraoperative dye visualization. Intraoperative gamma imaging may improve some protocols. This study was conducted to obtain preliminary experience and information regarding intraoperative imaging. Sixteen patients were enrolled: 8 in a protocol that included intraoperative counting and dye visualization (probe/dye), 8 in a protocol that involved intraoperative imaging, counting and dye visualization (camera/probe/dye). Preoperative imaging of all 16 patients was performed using a GE 500 gamma camera with a LEAP collimator (300 cpm/μCi). The results of this imaging were not, however, given to the surgeon until the surgeon had completed the procedures required for the study. A Care Wise C-Trak probe was used for intraoperative counting. A Gamma Medica Inc. GammaCAM/OR (12.5 × 12.5 cm FOV) with a LEHR collimator (135 cpm/μCi) was used for intraoperative imaging. Times from start of surgery to external detection of a radioactive focus and to completion of excision of SLNs were recorded. Foci were detected preoperatively via imaging in 16/16 patients. Intraoperative external detection using the probe was accomplished in less than 4 min (mean = 1.5 min) in 15/16 patients, and via intraoperative imaging in 6/8 patients. The average time for completion of excision of nodes was 19 min for probe/dye and 28 min for camera/probe/dye. In one probe/dye case, review of the preoperative images prompted the surgeon to resume axillary dissection and remove one additional SLN.

References (8)

  • SchillaciO et al.

    Sentinel node detection with imaging probe

    Tumori

    (2002)
  • YamaguchiY et al.

    Evaluation of hand-held gamma camera with 1-mm NaI(Tl) pixels

    SPIE Proc

    (2002)
  • PitreS et al.

    A hand-held imaging probe for radioguided surgery: Physical performance and preliminary clinical experience

    Eur J Nucl Med Mol Imaging

    (2003)
  • AbeA et al.

    Performance evaluation of a hand-held semiconductor (CdZnTe)-based gamma camera

    Eur J Nucl Med Mol Imaging

    (2003)
There are more references available in the full text version of this article.

Cited by (19)

  • High resolution portable gamma cameras

    2022, Nuclear Medicine and Molecular Imaging: Volume 1-4
  • Use of intraoperative nuclear imaging leads to decreased anesthesia time and real-time confirmation of lesion removal

    2018, Journal of Pediatric Surgery
    Citation Excerpt :

    Intraoperative nuclear imaging is an important technical advance in radioguided surgery. Adult studies enumerate the benefits including better visualization of nodes particularly near the injection site and determination of postexcision radioactivity [9–14]. These adult studies show precise and reproducible localization including depth of the nodes [10–13].

  • Sentinel Lymph Node Biopsy Procedures

    2017, Seminars in Nuclear Medicine
    Citation Excerpt :

    Time constraints can be dictators in this context. There are efforts to develop devices with various sizes of fields of view: small, ~5 cm × 5 cm; relatively small, ~10 cm × 10 cm; moderate, ~20 cm × 20 cm; moderately large ~30 cm × 40 cm.131-139 Note that the field of view of a conventional gamma camera is ~40 cm × 50 cm.

  • Mobile gamma cameras in breast cancer care - A review

    2013, European Journal of Surgical Oncology
  • Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applications

    2013, Physica Medica
    Citation Excerpt :

    In many cases, a single hot spot on preoperative imaging represented 2 or more sentinel lymph nodes adjacent to each other. Though Scopinaro et al. measured a significant decrease of biopsy time in breast cancer sentinel node biopsy with the use of SGC, other authors report that the detection using SGC combined with gamma probe and dye method requires a longer procedure time [12,79]. Although one of the principal advantages of SCG in sentinel lymph node biopsies is real-time imaging, a longer acquisition time may be needed to detect and localize low levels of activity.

View all citing articles on Scopus
View full text